For the configuration of the KELLER cellular devices we developed “PressureSuite Desktop”.
PressureSuite Desktop is available on the KELLER Website
The current value of a channel can only be retrvieved, if they are already configured active on the device.
This function checks for incoming configurations for example sent by the PressureSuite cloud.
The device can send useful information such as battery voltage, battery capacity, humidity etc.
If ‘Alarm Trigger Value’ >= ‘Alarm Un-Trigger Value’, then the alarm will be sent above a certain level
An alarm message is triggered if the measured value of the selected channel is greater than the ‘Alarm Trigger Value’. During this period the alarm will be sent X times if the measured value is still greater than the ‘Alarm Un-Trigger Value’ (Hysteresis = ‘Alarm Trigger Value’ – ‘Alarm Un-Trigger Value’).
If ‘Alarm Trigger Value’ < ‘Alarm Un-Trigger Value’, then the alarm will be sent below a certain level
An alarm message is triggered if the measured value of the selected channel is less than the ‘Alarm Trigger Value’. During this period the alarm will be sent X times if the measured value is still lower than the ‘Alarm Un-Trigger Value’ (Hysteresis = ‘Alarm Un-Trigger Value’ – ‘Alarm Trigger Value’).
NOTE: If the alarm condition is active and X alarm messages are sent no more alarm messages will be sent. The alarm is only re-armed when the ‘Alarm Un-Trigger Value’ condition is fulfilled.
There are essentially 3 different calculation types.
At water height above probe (E), the water column/water height above the probe is measured.
At depth to water (F), the distance from the upper edge of the measuring point to the water surface is determined. For the calculation of the depth upper edge of the measuring point to the water surface, the installation length B must be known.
At water level related to sea level (G) the water level/water level related to sea level is calculated. With this infor- mation, the measured values from different locations can be compared with each other. For this calculation, the installation length B and the height above sea level of the upper edge of the measuring point are required.
We recommend using FTP instead of E-Mail.
Test FTP connection Checks the connection to the from the computer to the configured FTP server with the provided credentials and prompts success or failure.
Send Configuration FTP Sends the current device configuration to the configured FTP server.
Send Measuring Data FTP Sends all the stored measurements that were not yet sent to the configured FTP server.
Send Configuration Email Sends the current device configuration to the configured E-Mail address.
Send Measuring Data Email Sends all the stored measurements that were not yet sent to the configured E-Mail address.